Input | Model Capacity (VA/W) Phase Rated Voltage Voltage Range Frequency Range Power Factor Current THDi Bypass Voltage Range ECO Range Generator Input |
3000VA 2700W Single Phase & Ground 200/208/220/230/240VAC 110-290V* 50Hz-60Hz (Auto-Detect) > 0.98 <7% at 100% Non-Linear Load Max. Voltage; -45% Optional -20%~-30% Frequency Protection Range: +/-10% Same As The Bypass Support |
Output | Phase Rated Voltage Power Factor Voltage Regulation Frequency - Utility Mode - Battery Mode Crest Factor THD Wave Form |
Single Phase & Ground 200/208/220/230/240VAC 0.9 +/- 2% 50Hz or 60Hz (Synchronized to Mains) 50Hz-60Hz +/- 0.02% Hz 3:1 < 3% with Linear Load < 5% with non Linear Load Pure Sine Wave |
Efficiency | AC Mode ( Full Load ) Battery Mode ( Full Load ) ECO Mode ( Full Load ) |
Up to 90% >88% >94% |
Battery | Voltage Capacity (Standard Unit) Back up Time Recharge Time to 90% Charging Current Battery Socket |
72Vdc 12V/9Ah Full load 5 min, 15-30 min ( Depend on load), Estimated remaining time display on the LCD 4-5 Hours 1.4A Anderson Like PowerPole Modular Connectors |
Transfer Time | Utility to Battery; 0ms, Utility to Bypass <4ms | |
Protection | Overload - AC Mode - Batt. Mode - Bypass Mode Short Circuit Overheat Battery Low Self-Diagnostics EPO Battery Noise Suppression |
Load <100%-150%; 30S; Load >150%; 300ms then shutdown UPS completely Load <100%-150%; 30S; Load >150%; 300ms then shutdown UPS completely Load >130%; 60S then shutdown output Hold Whole System Line mode; Switch to Bypass; Battery Mode, shutdown UPS immediately Alarm and Switch off Upon Power On and Software Control Shutdown UPS immediately Advanced Battery Management Compiles with EN962040-2 |
Display | Status LED & LCD Reading on the LCD |
Load/Battery/Input/Output/Operating Mode information Load/Battery/Input/Output/Operating Mode information |
Physical | Dimnsion (WxHxD) mm. Weight (Kilogram) Input Connection Output Connection External Battery Connection |
440 x 86.5 x 600 26.2 IEC320 C14-10A Universal x 6 IEC320 C19-16A x1 Anderson like PowerPole Modular connectors |
Communication Interface |
Smart RS232/USB Port Communication slot RJ 45 |
Support Windows Family, Linux, FreeDSB, etc. SNMP Card (independent to RS232) Built-in Power Surge, Lightning Protection Device |
Environment | Operating Temperature Storage Temperature Humidity Attitude Noise |
0 °C - 40 ° C -25 °C - +55 °C 0-90% non-condensing <1500 m. (derating while > 1500m) <50 dB (at 1 meter) |
Safety Conformance | CE |
Source : Unitec X4-3000RT